5 ways to measure bed level in thickeners - Precision ...

The selection of technology to measure bed level in thickeners depends on the process, environment and budget. The most popular methods are: manual samples, hydrostatic pressure, buoyancy-based system, fixed position ultrasound, mud diver

Developing MudMax™ for Paste Thickener Bed-Level …

Numerous methods have been employed to achieve reliable bed-level measurement, including bed pressure, ultrasonic, capacitance, nuclear, vibrating probes, divers, and floats (to name just a few). They are typically limited to measuring the level at one location in the thickener and they range from being very expensive to reasonably affordable.

MudMax™ Bed-Level Monitoring System

Patented Bed-Level Instrument That Brings Thickener Control Within Reach. MudMax™ uses advanced technology to deliver a first-of-its-kind bed-level monitoring system that provides 360-degree bed-level measurement inside thickeners and clarifiers. Multiple sensors located in the active bed-level area directly detect and accurately measure bed levels.

Paste thickener bed level measurement | Environmental XPRT

07-03-2016· Numerous methods have been employed to achieve reliable bed level measurement including bed pressure, ultrasonic, capacitance, nuclear, vibrating probes, divers and floats to name a few. They are typically limited to measuring the level at one location in the thickener and they range from being very expensive to reasonably affordable.

Bed level, Density and Solids: Measurement applications in ...

17-01-2020· Bed level, Density and Solids: Measurement applications in a Thickener tank - YouTube. Bed level, Density and Solids: Measurement applications in a Thickener tank. Watch later. Share. Copy link ...

SmartDiver - Mud Diver, Sludge Level Measurement, …

The Smart Diver is a ruggedised mud diver that provides measurement of mud levels, settling zones and overflow clarity in thickeners, clarifiers, washers and decanters. Tank profiling (suspended solids vs depth) is also provided, as it is specific gravity profiling and bed level measurement. For more information call +61 3 9786 1711.

Instrumentation and Control of Sedimentation Equipment

Some of the process variables that are commonly monitored on a thickener are torque, rake height, bed level, bed pressure, feed rate and density, underflow rate and density, settling rate, and overflow turbidity. Many of these are easily measured, while some can be difficult.

Tailings Thickeners | Hawk Measurement Systems

The Sonar Acoustic transmitter can be calibrated to work with two different densities. We can track the Compact Bed Level to control the underflow pump. We can also track a lighter density within the interface column that when affected by a settling problem with in the Thickener will rise hydraulically upwards towards the launders.

An intelligent control strategy for thickening process ...

10-09-2015· Through the online measurement of the thickener operation parameters including feed flow rate, mud bed level, and underflow concentration, an intelligent control strategy for thickener underflow and flocculant addition is proposed based on the mass balance model and expert rules.

Sludge level sensors and transmitters for sedimentation ...

To measure sludge level where clogging and fouling can occur (primary and secondary clarifiers, sludge tanks, thickeners, etc.), we recommend sensors with a wiper. For sludge level measurement in a secondary clarifier that has a surface skimmer or in clear water sedimentation tanks, you can use a standard sludge level detector.

Thickener & Clarifier Level Control ... - Hawk Measurement

Solutions for all Thickener Applications. HAWK has designed and developed a wide variety of precision instruments for thickener and clarifier control. Whether there are varying densities, hydraulic imbalance, suspended solids, and build-up, HAWK has the ability to measure and monitor bed levels accurately. The ORCA Sonar series will measure up ...

Optimise thickener efficiency for maximum profitability ...

Depending on the application conditions, different techniques are employed to determine a thickener’s bed-level: • Theoretical bed-level based on the calculation of the average density of a constant height using a hydrostatic... • Submerged ultrasound sludge blanket transducer to sense reflections ...

An intelligent control strategy for thickening process ...

10-09-2015· Through the online measurement of the thickener operation parameters including feed flow rate, mud bed level, and underflow concentration, an intelligent control strategy for thickener underflow and flocculant addition is proposed based on the mass balance model and expert rules.

Thickening - Resource Book

level if it is sufficiently flocculated to produce the desired clarity and the underflow density. The increase in flocculation efficiency realised in high rate thickeners may increase in a bulk settling rate 2 to 10 times over that obtained in a conventional thickener, thus reducing the …

index [www.clarometer.com]

Total Thickener Control. Bed Level measurement. Overflow Turbidity. Tailings Dewatering. High temperature process sampling. Automatic cleaning. Clarity wedges. Sample scoops. Scale probes.

Instruments for bed level detection - Coastal Wiki

Acoustic bed level detection (echo-sounding instruments) The most common system for measuring water depth is the single-beam echo sounder. This sonar instrument uses a transducer that is usually mounted on the bottom of a ship. Sound pulses (usually 210 KHz for surface detection) are sent from the transducer straight down into the water.

(PDF) THICKENER DESIGN, CONTROL AND …

measured pressure during operat ions ... suppliers need to take current thickener designs to the next level and into ... the thickening process is dominated by the bed consolidation rather than ...

Sludge level sensors and transmitters for sedimentation ...

To measure sludge level where clogging and fouling can occur (primary and secondary clarifiers, sludge tanks, thickeners, etc.), we recommend sensors with a wiper. For sludge level measurement in a secondary clarifier that has a surface skimmer or in clear water sedimentation tanks, you can use a standard sludge level detector.

How to Use | Thick-It

Add level measured thickener into a dry, empty glass. Pour entire amount of desired cold or hot liquid into glass over thickener powder. Immediately begin stirring briskly with fork, spoon, or whisk for 30 seconds to 1 minute. With water and juices, let stand for 1-2 minutes and serve. With milk and supplements, let stand for 3-6 minutes and serve.

LEVEL MEASUREMENT

level measurement instruments currently used in petrochemical industries. REASONS FOR LEVEL MEASUREMENT Safety - in boilers, a dangerous state can develop if the water level varies outside certain limits. Economy - Good level control of solids is also desirable, excessive build up in hoppers can be expensive to clear.

An intelligent control strategy for thickening process ...

10-09-2015· Through the online measurement of the thickener operation parameters including feed flow rate, mud bed level, and underflow concentration, an intelligent control strategy for thickener underflow and flocculant addition is proposed based on the mass balance model and expert rules.

MudMax™ Bed-Level Monitoring System for Thickener …

06-11-2019· WesTech’s MudMax™ uses advanced technology in a first-of-its-kind bed-level monitoring system that delivers 360-degree measurements from inside the thickener...

Instruments for bed level detection - Coastal Wiki

Acoustic bed level detection (echo-sounding instruments) The most common system for measuring water depth is the single-beam echo sounder. This sonar instrument uses a transducer that is usually mounted on the bottom of a ship. Sound pulses (usually 210 KHz for surface detection) are sent from the transducer straight down into the water.

Estimating true level in a thickener using a conductivity ...

Level in a thickener can be estimated from the conductance profile (conductance vs depth). Using a conductivity probe the original 0–1 level scale has been calibrated to read “true” level as ...

(PDF) THICKENER DESIGN, CONTROL AND …

measured pressure during operat ions ... suppliers need to take current thickener designs to the next level and into ... the thickening process is dominated by the bed consolidation rather than ...

A description of the sedimentation process during dynamic ...

For a given thickener solids flux or throughput the rate of rise of the mud bed interface is constant with time and therefore it is a useful parameter to measure for controlling the level of the mud bed within the thickener (Figure 3). Critical Sedimentation Point Time Interface Height Mud bed Liquid/solid A B C A C D

How to Use | Thick-It

Add level measured thickener into a dry, empty glass. Pour entire amount of desired cold or hot liquid into glass over thickener powder. Immediately begin stirring briskly with fork, spoon, or whisk for 30 seconds to 1 minute. With water and juices, let stand for 1-2 minutes and serve. With milk and supplements, let stand for 3-6 minutes and serve.

Level Measurement | Emerson US

Level, interface and volume measurement for basic, challenging, and extreme conditions in any application. Reliable, easy-to-use level instrumentation, designed with you in mind Our wide range of devices for liquids and solids measurement covers the whole spectrum from basic point level detection to challenging continuous level, interface and volume measurement, even in extreme conditions.

LEVEL MEASUREMENT

level measurement instruments currently used in petrochemical industries. REASONS FOR LEVEL MEASUREMENT Safety - in boilers, a dangerous state can develop if the water level varies outside certain limits. Economy - Good level control of solids is also desirable, excessive build up in hoppers can be expensive to clear.

Best Practices for Level Measurement

Select the Right Liquid Level Sensor 4 it’s important to consider a variety of factors when choosing the type of technology Properly Measure Liquid/Liquid Interfaces 9 Follow a simple rule for location of level gauge nozzles Improve Reactor Vessel Measurement 12 non-contact radar level meter speeds production and boosts worker safety Ad Index